Polyisocyanurate insulation above the sheathing and approximately 91 4 in.
Unvented shed roof with above deck installation.
Original roof uninsulated rafter framing with board roof deck.
Dallas tx is located in a mixed humid climate region.
Note that this roof assembly has rigid insulation installed above the roof deck in order to control the condensation potential.
Test roofing membranes for integrity prior to covering from below.
As it cools it can t hold as much moisture.
Of cellulose insulation in the rafter cavities the roof shown here has an r value of approximately 63.
Yes skylights went in.
Another approach is to build a cupola or ventilated doghouse in the middle of the low slope roof an approach championed by joe lstiburek.
With three layers of 11 2 in.
Deck for a thick roof rigid foam insulation installed above the roof assembly can create an energy smart roof.
Martin s post focuses on the marketing of owens corning 039 s propink unvented attic insulation system.
In unvented flat or low slope roofs with parapets perform a full flood test to ensure leak free installation of roofing membrane.
Rigid foam above roof sheathing.
The three layers of foam help to seal air leaks but to make this assembly perform well you need to incorporate some unconventional details.
You can install all of the insulation above the roof sheathing but the foam has to be thick enough to meet minimum code requirements for ceiling r value.
But a space needs to be a space or what is the point.
The rigid foam will be fairly thick see sidebar how much insulation.
Yes unvented roof assemblies can be insulated with fiberglass a wufi post and not just in climate zones 2b amp.
Unvented roof diagram i know this is a very basic example so if you want to read more on the topic i ve put some additional reading for unvented roofs at the end of this article.
That excess moisture ends up as drops of condensation on the roof.
Warm wet air rises and meets the cold roof and cools.
Furring straightens out rafter plane for smooth plaster finish.
This roof assembly has no insulating sheathing installed above the roof deck.
Figure 4 shows the potential for condensation of an unvented roof assembly in dallas tx.
Essentially condensation occurs at night when the temperature inside a building is warmer than outside.
Simply put unvented roofs get rid of the vents and move the thermal air control and moisture boundaries to the roof deck.
Photograph 1 above left.
Rigid foam insulation installed above the roof assembly can create an energy smart roof.
With rigid foam above the sheathing and cellulose in the rafter cavities this roof is about r 63.
Yes they are big thermal holes.
Four options for building an unvented roof assembly.