You ll now need to take a tee fitting and install it to the drain line with the use of pvc glue where the line meets the.
Studor vent in attic.
Studor maxi vent mini vent tec vent watermark wm 022830 march 27 2019 3 43 pm 285 56 kb.
Sewer gas can not only be noxious it can be explosive plus the moisture in it could condense creating mold and rot.
The negative pressure activated one way vents to protect the trap seals in the drainage system by allowing the intake of air so that the right level of pressure within the drainage system is maintained.
Providing a range of valves and complete systems to limit pressure fluctuations guaranteeing the integrity of the traps studor will support you with solutions and services to ensure you eliminate drainage smells with a maintenance free drainage system.
Studor vents are utilized when a drain line vent is not connected to toilets.
Air admittance valves aka studor vents are negative pressure activated one way mechanical valves.
Used most commonly at an island sink or vanity the vents are also located in the attic to prevent the roof penetrations as seen above on the front roof line elevation.
Studor offers high quality solutions for all commercial and residential buildings eliminating the need for roof penetrations and extensive group vent piping.
The aluminium cover may be painted to blend with the surroundings.
Air admittance valves installed in insulated attic or ceiling spaces shall be installed in free air at least 6 inches above the insulation.
The maxi vent is discreet it can be installed in the attic area or even below the flood level of the highest connected branch.
World leading air admittance valves.
E 8 4 8 air admittance valves shall be the same size as the vent pipe to which they are connected.
After the tee fitting has been installed attach the drain line from the tee to the toilet.
It can be stacked to provide additional dfu drainage fixture capacity a drainage measurement set forth by the uniform plumbing code.
Studor aavs eliminate the need for passive pipe venting and costly roof penetrations with world leading performance by their unique and patented design.
It may also be installed outside the building when used in conjunction with the aluminium cover and polystyrene cap.
Locate the toilet drain line and use a hacksaw to cut it 2 inches from the wall.
Use the studor maxi vent on drainpipes from 3 to 4 inches the vent is manufactured primarily for commercial buildings and is the largest one made by studor with a correspondingly large venting capacity.